nVent Hoffman Enclosure Heat Exchangers

Air-to-air heat exchangers deliver convection cooling to heat producing electrical equipment using a closed loop cooling system. The closed loop design cools and recirculates the air inside an electrical enclosure, while isolating electrical components from environments that may contain contaminants. 

The air-to-air heat exchangers utilize copper heat pipes surrounded by extruded fins. The fins increase the surface area allowing faster heat absorption and dissipation. The copper pipes contain a phase changing liquid that absorbs heat from the heated enclosure where it is then converted to vapor. The heated vapor automatically moves to the cooler end of the heat pipe, which is exposed to the cooler ambient air outside the enclosure. 

The excess heat is expelled out and the vapor is changed back into liquid, which then moves back towards the warmer end of the heat pipe. The heating and cooling process repeats continuously. Air-to-water heat exchangers use the same principle of temperature differential, but they alter the internal air temperature by forcing air across water coils. 

Found 39 items
Filters
Found 39 items
Manufacturer
Hoffman (39)
Component
Heat Exchanger (39)
Sub Component
Air To Air Heat Exchanger (25)
Air To Water Heat Exchanger (8)
Line
Climaguard TX (11)
Climaguard WCHE (8)
Climaguard XR (14)
AC Type
Heat Exchanger (33)
AC Amperage
0.1 Amp (1)
0.3 Amp (2)
0.5 Amp (2)
0.6 Amp (3)
0.8 Amp (2)
0.9 Amp (3)
1 Amp (1)
1.2 Amp (1)
1.3 Amp (1)
1.4 Amp (1)
AC Voltage
24 VDC (1)
48 VDC (2)
115 VAC (15)
230 VAC (20)
AC Height
5.5" (1)
7.5" (1)
16" (2)
19.7" (2)
21" (2)
24" (3)
30" (4)
34" (2)
37.4" (2)
37" (4)
AC Width
7.9" (2)
8" (2)
11" (6)
13" (5)
15.7" (2)
16" (12)
20" (7)
23.6" (1)
28.3" (1)
AC Depth
3.9" (1)
4.5" (1)
4" (4)
5.9" (1)
5" (2)
6" (8)
7.5" (1)
8" (3)
9" (6)
10" (2)
AC Composition
Steel (32)
AC Environment
Indoor (22)
Outdoor-Indoor (10)
AC Maximum Ambient Temp
122 F (8)
140 F (14)
149 F (10)
AC Minimum Ambient Temp
-20 F (14)
-40 F (10)
50 F (8)
AC NEMA Rating
NEMA Type 4 (10)
NEMA Type 12 (32)
AC Watts
600 (1)
950 (1)
1500 (1)
2150 (1)
3150 (1)
3400 (1)

More Information about nVent Hoffman Enclosure Heat Exchangers

nVent Hoffman ClimaGuard Air-to-Air Outdoor Heat Exchangers utilize closed-loop cooling while sealing out dirt, dust, corrosive elements and wind-driven rain. They feature a double-crimped and dip-sealed core, allowing efficient thermal transfer while ensuring maximum protection against leaks. The units can be surface or recess mounted to an enclosure and provide a tight seal against air and water infiltration.

nVent Hoffman ClimaGuard Air-to-Air Indoor Heat Exchangers utilize closed-loop cooling while sealing out dirt, dust, corrosive elements and wash down water. They allow efficient thermal transfer while ensuring maximum protection against leaks. The units can be surface or recess mounted to an enclosure and provide a tight seal against air and water infiltration.

nVent Hoffman ClimaGuard Air-to-Water Indoor Heat Exchangers remove heat from an enclosure by flowing enclosure hot air across a water-cooled exchanger core. Ambient operating temperatures can range from 50 to 158 degrees F while inside enclosure temperatures can range from 50 to 122 degrees F. These units require an available cooled water source. They include a condensation recovery system and a condensation discharge pipe.

Industrial Enclosure Accessories and Modifications

Lighting kits

Lighting kits are often used in outdoor applications. There are many different styles of lighting kits that can be used, but LEDs have become the preferred lighting solution in the past several years.

Pressure switches

Pressure switches operate on a spring and react to the cabinet door opening and closing. They can be used for lights, intrusions alarms and exhaust fans.

Passive Air Vents

Passive air vents allow natural air circulation to flow through a cabinet providing proper ventilation.

Enclosure Fans

Enclosure air fans are used when more ventilation is required. The size of the fan will depend on the size of the enclosure as well as the amount of air that needs to be circulated.

Air Conditioners

Air conditioners are used when ambient air circulation is inadequate to cool the cabinet. The air conditioner size will depend on the enclosure size, ambient air temperature and heat generated within the cabinet.

Heaters

Heaters are used when a cabinet is located in areas that may be exposed to cold temperatures.

Locking Mechanisms

Locking mechanisms are used to secure cabinets.

Conduit Hole Seals

Conduit hole seals are used on cabinets that have holes that need to be plugged after conduit has been removed.