Code: 177353
ACI 140673 A/TT100-LT-INW-4"-4-GD 100 Ohm Immersion RTD
Normally In Stock
ACI 140673 Transmitter w/ 100 Ohm RTD, Low Temperature Immersion, No Well, 4" 316SS, 4-20mA Output
Condition: New
Backordered with 10-12 week lead time$334.80
Sale Price
$279.00
Tariff Status
Tariff may apply if shipping to the United States. Tariff costs are calculated and will be displayed in the shopping cart.
Need a large quantity or a custom solution?
Add this product to your job, favorites list or request a quick quote for volume pricing and lead time information. Our team is ready to assist with any special requirements.
Related Products
Description
The ACI Low Temperature Immersion Series sensors and transmitters are a single point immersion sensor featuring a three wire RTD sensor assembly using Teflon insulated lead wires and a 316 Series stainless steel probe. The three wire sensors can be used with a two wire transmitter by connecting the two (Red) colored wires to one of the RTD Terminal blocks with the 3rd (White) wire going to the second RTD Terminal block. The purpose of the 3rd wire is to compensate for external lead wire resistance that will affect the accuracy of your sensor output when using with a three wire temperature transmitter or sensor configuration on your Building Management System or PLC (Programmable Logic Controller. ACI recommends the use of 18 AWG lead wires to reduce the external lead wire resistance when using a Platinum RTD. The operating specifications are for both the sensor and transmitter as designated in the specification table. The overall accuracy of the temperature transmitter must be calculated using the transmitter calibrated accuracy plus that of the sensor error over temperature unless ordering as a TTM matched transmitter. Standard enclosure options include the “-GD” Galvanized or “-BB” Aluminum weather proof enclosure. NIST Certificates are available for all of the configurations listed in the ordering grid on the back of the product data sheet. For best accuracy, ACI recommends the use of the TTM100 or TTM1K Series Matched transmitters since they include a second calibration step in which the RTD and transmitter are calibrated together as a system, in order to remove most of the sensor error over the calibrated temperature span of the transmitter. Applications: Chillers, Pharmaceutical, Refrigeration, Process Cooling, Industrial Process Control
Specifications
Manufacturer
ACI
Component
RTD
(Instrument-Sensor) Type
100 Ohm
(Instrument-Sensor) Mounting
Immersion
Features
The ACI Low Temperature Immersion Series sensors and transmitters are a single point immersion sensor featuring a three wire RTD sensor assembly using Teflon insulated lead wires and a 316 Series stainless steel probe
The three wire sensors can be used with a two wire transmitter by connecting the two (Red) colored wires to one of the RTD Terminal blocks with the 3rd (White) wire going to the second RTD Terminal block
The purpose of the 3rd wire is to compensate for external lead wire resistance that will affect the accuracy of your sensor output when using with a three wire temperature transmitter or sensor configuration on your Building Management System or PLC (Programmable Logic Controller
ACI recommends the use of 18 AWG lead wires to reduce the external lead wire resistance when using a Platinum RTD
The operating specifications are for both the sensor and transmitter as designated in the specification table
The overall accuracy of the temperature transmitter must be calculated using the transmitter calibrated accuracy plus that of the sensor error over temperature unless ordering as a TTM matched transmitter
Standard enclosure options include the “-GD” Galvanized or “-BB” Aluminum weather proof enclosure
NIST Certificates are available for all of the configurations listed in the ordering grid on the back of the product data sheet
For best accuracy, ACI recommends the use of the TTM100 or TTM1K Series Matched transmitters since they include a second calibration step in which the RTD and transmitter are calibrated together as a system, in order to remove most of the sensor error over the calibrated temperature span of the transmitter.