ACI 140457 A/1K-3W-HT-INW-6"-GD Immersion RTD
Normally In Stock
Code: 177321
ACI 140457 1,000 Ohm (Three Wires) RTD, High Temperature Immersion, no Well, 6" 316SS, Galvanized Enclosure
Condition: New
Usually ships Same Day or Next Day$124.20
Sale Price
$103.50
Tariff Status
Tariff may apply if shipping to the United States. Tariff costs are calculated and will be displayed in the shopping cart.
Need a large quantity or a custom solution?
Add this product to your job, favorites list or request a quick quote for volume pricing and lead time information. Our team is ready to assist with any special requirements.
Description
ACI 140457 1,000 Ohm (Three Wires) RTD, High Temperature Immersion, no Well, 6" 316SS, Galvanized Enclosure
Specifications
Manufacturer
ACI
Component
RTD
(Instrument-Sensor) Mounting
Immersion
Features
The ACI High Temperature Immersion Series sensors and transmitters are a single point immersionsensor featuring a three wire RTD sensor assembly using Nickel Fiberglass Lead wires, a 316 Seriesstainless steel probe, and a Machined 304 SS Steel thermowell
The “INW” version of the productcan be ordered without the thermowell for applications in which there is an existing thermowell,increased design parameters or other materials are required for higher corrosion resistance
Thethree wire sensors can be used with a two wire transmitter by connecting the two (Red) coloredwires to one of the RTD Terminal blocks with the 3rd wire (White) wire going to the second RTDTerminal block
The purpose of the 3rd wire is to compensate for external lead wire resistancethat will affect the accuracy of your sensor output when using with a three wire temperaturetransmitter or sensor configuration on your Building Management System or PLC (ProgrammableLogic Controller
ACI recommends the use of 18 AWG lead wires to reduce the external lead wireresistance when using a Platinum RTD
The operating specifications are for both the sensor andtransmitter as designated in the specification table
Standard enclosure options include the“-GD” Galvanized or “-BB” Aluminum weather proof enclosure
NIST Certificates are available for all of the configurations listed in the orderinggrid on the back of the product data sheet
For best accuracy, ACI recommends the use of the TTM100 or TTM1K Series Matched transmitters witha 3 or 5 Point NIST Calibration Certificate since they include a second calibration step in which the RTD and transmitter are calibrated together asa system, which removes most of the sensor error over the calibrated temperature span of the transmitter.