ACI 148565 QIRF-448AX-0 Refrigerant,R448A NEMA 4X Gas
Normally In Stock
Code: 179531
ACI 148565 REFRIGERANT SENSOR
Condition: New
Usually ships Same Day or Next Day$2645.68
Sale Price
$2204.73
Tariff Status
Tariff may apply if shipping to the United States. Tariff costs are calculated and will be displayed in the shopping cart.
Need a large quantity or a custom solution?
Add this product to your job, favorites list or request a quick quote for volume pricing and lead time information. Our team is ready to assist with any special requirements.
Description
The QIRF Refrigerant Gas Detectors are the second generation of a proprietary designed gas detector that is easily configured to meet the International Mechanical Code, ASHRAE 15 and B52 requirements. These transmitters are engineered to address the deficiencies inherent with solid-state sensors. Infrared technology facilitates specific gas type refrigerant detection without any cross-sensitive interferences. Standard features include a digital display, three user configurable relays, buzzer, horn/strobe output, NEMA 4X enclosure and non-intrusive calibration. Sensor Housings are thermally controlled at elevated temperatures to eliminate errors due to condensation forming and from temperature fluctuations allowing operations in temperatures from -49 to 149ºF (-45 to 65ºC). Analog outputs of 4-20 mA and or 2-10 VDC are available along with RS-485 Communications that can be used with a Modbus RTU or proprietary OptoMux communication protocol for use with any of the standalone gas controller such as the Q4C, M-Controller or Q-Controller. A Zero gas of 20.9% Oxygen with the balance Nitrogen should be used to perform a Zero calibration while a known concentration of any span gas can be used to perform yearly bump testing and calibration. Never use 100% Nitrogen gas to perform a Zero calibration on the QIRF transmitters. Calibration gases and a 0.4 to 0.6 liter/minute ‑ow limiting gas regulator are not available through ACI and should be purchased through your local gas supply company or on-line companies such as Portagas® (Praxair®, Inc.) or Mesa Specialty Gases®. ACI also offers a full line of horns and strobes that can be used with the Gas detectors or building management system to alert building occupants of an alarm condition in order to meet the B-52 or other code requirements. Refer to all applicable Federal, State, Provincial and Local Health and Safety laws and regulations before using these products.
Specifications
Manufacturer
ACI
Component
Gas
(Instrument-Sensor) NEMA Protection
NEMA 4X
(Instrument-Sensor) Type
R448A Refrigerant
Features
The QIRF Refrigerant Gas Detectors are the second generation of a proprietary designed gas detector that is easily configured to meet the International Mechanical Code, ASHRAE 15 and B52 requirements
These transmitters are engineered to address the deficiencies inherent with solidstate sensors
Infrared technology facilitates specific gas type refrigerant detection without any cross-sensitive interferences
Standard features include a digital display, three user configurable relays, buzzer, horn/strobe output, NEMA 4X enclosure and non-intrusive calibration
Sensor Housings are thermally controlled at elevated temperatures to eliminate errors due to condensation forming and from temperature fluctuations allowing operations in temperatures from -49 to 149ºF (-45 to 65ºC)
Analog outputs of 4-20 mA and or 2-10 VDC are available along with RS-485 Communications that can be used with a Modbus RTU or proprietary OptoMux communication protocol for use with any of the standalone gas controller such as the Q4C, M-Controller or Q-Controller
A Zero gas of 20.9% Oxygen with the balance Nitrogen should be used to perform a Zero calibration while a known concentration of any span gas can be used to perform yearly bump testing and calibration
Never use 100% Nitrogen gas to perform a Zero calibration on the QIRF transmitters
Calibration gases and a 0.4 to 0.6 liter/minute flow limiting gas regulator are not available through ACI and should be purchased through your local gas supply company or on-line companies such as Portagas® (Praxair®, Inc.) or Mesa Specialty Gases®
ACI also offers a full line of horns and strobes that can be used with the Gas detectors or building management system to alert building occupants of an alarm condition in order to meet the B-52 or other code requirements
Refer to all applicable Federal, State, Provincial and Local Health and Safety laws and regulations before using these products.