ACI 147595 A/CO2-R2SO-AN-A10-G5 Carbon Dioxide Room Gas
Normally In Stock
Code: 179194
ACI 147595 Carbon Dioxide Sensor, Room, 0-2000 PPM, (0-5V, 0-10V, 4-20mA), Temp (10K Type III), Setpoint (0-1K), Blue/Red Sticker, Override
Condition: New
Usually ships Same Day or Next Day$284.87
Sale Price
$237.39
Tariff Status
Tariff may apply if shipping to the United States. Tariff costs are calculated and will be displayed in the shopping cart.
Need a large quantity or a custom solution?
Add this product to your job, favorites list or request a quick quote for volume pricing and lead time information. Our team is ready to assist with any special requirements.
Description
The ACI CO2 (A/CO2 R2) room transmitter monitors the carbon dioxide (CO2) levels in industrial, school, and office type environments. The concentration of CO2 is a strong indication of the overall indoor air quality. The A/CO2 Series is based on a single beam, non dispersive infrared technology and is a cost efficient solution for measuring carbon dioxide (CO2) levels for building climate control. In addition, ABC software eliminates the need for manual calibration. Carbon Dioxide concentration is measured up to 2,000 ppm and is converted into proportional analog outputs. The factory default output is 4-20 mA, whereas 0-5 VDC and 0-10 VDC outputs are able to be field selected via integral dip switches. Thermistor temperature outputs, along with setpoint and override, are available as options for room configurations. The A/CO2 Series provides data which can be used in conjunction with a Building Automation System or Demand Control Ventilation to decrease energy consumption while creating a healthier indoor climate. The A/CO2 Series is covered by ACI's Five (5) Year Limited Warranty. Carbon Dioxide sensors or transmitters for HVAC, Building Automation Systems, or ANSI/ASHRAE Standard 62.1 2007. Typical applications include: schools, office buildings, auditoriums, gymnasiums, shopping malls, theatres, Demand Control Ventilation, or economizers.
Specifications
Manufacturer
ACI
Component
Gas
(Instrument-Sensor) Type
Carbon Dioxide
Features
The ACI Carbon Dioxide Room Series (A/CO2-R2) monitors the carbon dioxide (CO2) levels in commercial, school, and office-type environments
The concentration of CO2 is a strong indication of the overall indoor air quality
The A/CO2 Series is based on a single beam, nondispersive infrared technology and is a cost-efficient solution for measuring carbon dioxide levels for building climate control
In addition, ABC software eliminates the need for manual calibration
Carbon Dioxide concentration is measured up to 2,000 ppm and is converted into proportional analog outputs
The factory default outputs are 0-10 VDC (Output 1) and 4-20 mA (Output 2), whereas 0-5 VDC is field selectable via integral dip switches
Thermistor temperature outputs, along with setpoint and override, are available as options for this configuration as well
Please see the order grid for the available sensor options
The A/CO2-R2 Series provides data which can be used in conjunction with a Building Automation System or Demand Control Ventilation to decrease energy consumption while creating a healthier indoor climate.