Code: 178271
ACI 144560 A/TT1K-LT-D-4"-4-BB Duct RTD
Normally In Stock
ACI 144560 Transmitter w/ 1,000 Ohm RTD, Low Temperature Duct, 4" 316SS, Galvanized Enclosure, 4-20mA Output
Condition: New
Backordered with 10-12 week lead time$299.16
Sale Price
$249.30
Tariff Status
Tariff may apply if shipping to the United States. Tariff costs are calculated and will be displayed in the shopping cart.
Need a large quantity or a custom solution?
Add this product to your job, favorites list or request a quick quote for volume pricing and lead time information. Our team is ready to assist with any special requirements.
Description
The ACI Low Temperature Duct Series sensors and transmitters are a single point duct sensor featuring a three wire RTD sensor assembly using Teflon Lead wires and a 316 Series stainless steel probe. The three wire sensors can be used with a two wire transmitter by connecting the two (Red) colored wires to one of the RTD Terminal blocks with the third wire (White) wire going to the second RTD Terminal block. The purpose of the third wire is to compensate for external lead wire resistance that will affect the accuracy of your sensor output when using with a three wire temperature transmitter or sensor configuration on your Building Management System or PLC (Programmable Logic Controller. ACI recommends the use of 18 AWG lead wires to reduce the external lead wire resistance when using a Platinum RTD. The operating specifications are for both the sensor and transmitter as designated in the specification table. Standard enclosure options include the “-GD” Galvanized or “-BB” Aluminum weather proof enclosure. NIST Certificates are available for all of the configurations listed in the ordering grid on the back of the product data sheet. For best accuracy, ACI recommends the use of the TTM100 or TTM1K Series Matched transmitters since they include a second calibration step in which the RTD and transmitter are calibrated together as a system, in order to remove most of the sensor error over the calibrated temperature span of the transmitter. Applications: Pharmaceutical, Liquid Nitrogen, Refrigerators, Freezers, Hydronic Heating, Remote Sensor Applications
Specifications
Manufacturer
ACI
Component
RTD
(Instrument-Sensor) Mounting
Duct
Features
The ACI Transmitter Duct Series features a two-wire, 4 to 20 mA loop powered output signal with an optional 3-Wire voltage output signal available
All transmitters include Zero and Span adjustments for field calibration and are calibrated using NIST Certified Calibration equipment
ACI recommends the use of an 18 to 22 AWG shielded cable for all temperature transmitter installations to help eliminate the possibility of noise being introduced onto the signal lines
The sensor assemblies are manufactured using colored Etched Teflon lead wires and ACI’s proven double encapsulation process to eliminate the effects of moisture on the sensors as well as increased response times using our high quality, thermally conductive epoxy
The duct sensors include a foam pad to properly seal the duct and limit vibration once installed
Optional NEMA/IP rated weather proof enclosures are available as specified on the back of the product data sheet
For best accuracy, ACI recommends the use of the A/TTM Series Matched transmitters with 3 or 5 Point NIST Calibration Certificate, since they include a second calibration step in which the RTD and transmitter are calibrated together as a system.