Temperature Transmitters & Transducers

Industrial DIN-rail mounted signal interface and conditioning modules including intrinsic safety barriers, programmable signal isolators, and analog signal converters. These devices provide electrical isolation, signal conversion, and safe interfacing between field instruments and PLC or DCS control systems in industrial automation and hazardous area applications.

Temperature transmitters and transducers convert signals from temperature sensors into standardized electrical outputs that industrial control systems can reliably process. These devices accept inputs from thermocouples and RTDs and condition the signal into common analog formats such as 4–20 mA, 0–10 V, or millivolt outputs, depending on the application. By providing a stable, linearized output, they help improve measurement consistency and simplify integration with PLCs, controllers, recorders, and data acquisition systems.

Temperature transmitters are commonly used when signals must travel longer distances or when electrical noise and ground potential differences may impact measurement accuracy. Current loop outputs such as 4–20 mA are often preferred for industrial environments because they are less susceptible to signal degradation over long cable runs. Many transmitter designs also support features such as galvanic isolation and configurable ranges, making them suitable for process control applications where reliable temperature feedback supports product quality, equipment protection, and operational safety.

Temperature transducers are often used to describe devices that convert temperature into a voltage-based output or discrete electrical response. In some monitoring and safety applications, transducer-style outputs may be used where a voltage signal is preferred or where a device changes state at a defined temperature threshold. Selecting between a transmitter and a transducer typically depends on the required output type, wiring distance, noise exposure, and the input requirements.

Found 47 items
Normally In Stock
Omega HX86BA HIGH TEMP (120C) RH TX
Free U.S Ground shipping
$3426.36
$2855.30
Normally In Stock
Omega HX86BA-W WALL MOUNT TEMP/RH/BARROMETRIC
Free U.S Ground shipping
$2906.41
$2422.01
Normally In Stock
Omega HX86A HIGH TEMP (120C) RH TX
Free U.S Ground shipping
$2831.16
$2359.30
Normally In Stock
Omega HX86A-W WALL MOUNT TEMP/RH/DP XTR
Free U.S Ground shipping
$2900.90
$2417.42
Normally In Stock
Omega SPRTX-M1 RTD TRANSMITTER
Free U.S Ground shipping
$418.00
$348.33
Normally In Stock
Omega SPRTX-S1 RTD TRANSMITTER
Free U.S Ground shipping
$462.73
$385.61
Normally In Stock
Omega HX93BC-D TEMP/HUM DUCTMNT TX 4-20MA
Free U.S Ground shipping
$662.34
$551.95
Normally In Stock
Omega HX93BC-RP1 TEMP/HUM TX REM PROBE 4-20MA
Free U.S Ground shipping
$782.47
$652.06
Normally In Stock
Omega HX93BDC T/HUM TX WALL MOUNT DISPLAY 4-20MA
Free U.S Ground shipping
$1012.21
$843.51
Normally In Stock
Omega HX93BDC-D RH/T TRANS/DISPLAY DUCMNT4-20
Free U.S Ground shipping
$677.57
$564.64
Normally In Stock
Omega HX93BDC-RP1 T/RH DISPLY REMOTE PROBE 4-20
Free U.S Ground shipping
$1086.61
$905.51
Normally In Stock
Omega HX94C RH/TEMP TRANSMITTER
Free U.S Ground shipping
$738.80
$615.67
Normally In Stock
Omega HX94CNPT RH/TEMP TX W/1/2" NPT
Free U.S Ground shipping
$762.54
$635.45
Normally In Stock
Omega HX94CW RH/TEMP TX W/ 3'FT LEADS
Free U.S Ground shipping
$703.31
$586.09
Normally In Stock
Omega HX200HR Humidity Probe for Relative Humidity
Free U.S Ground shipping
$1566.31
$1305.26
Normally In Stock
Omega HX200HR-RS REMOTE MOUNT TEMP/RH XTR SELECT OUTPUT
Free U.S Ground shipping
$1776.78
$1480.65
Normally In Stock
Omega HX200HR-W WALL MOUNT TEMP/RH XTR CURRENT OUTPUT
Free U.S Ground shipping
$1521.65
$1268.04
Normally In Stock
Omega HX200HR-W-RS WALL MOUNT TEMP/RH XTR SELECT OUTPUT
Free U.S Ground shipping
$1877.10
$1564.25
Normally In Stock
Omega HX92BC HUM XMITTER WALL MNT 4-20MA CE
Free U.S Ground shipping
$520.38
$433.65
Normally In Stock
Omega HX92BC-D HUM XMITTER DUCT MNT 4-20MA CE
Free U.S Ground shipping
$563.44
$469.53
Normally In Stock
Omega HX92BC-RP1 HUM XMITTER REMOTE PROBE 4-20
Free U.S Ground shipping
$708.77
$590.64
Normally In Stock
Omega HX94BC RH/TEMP TRANSMITTER CURRENT STANDARD
Free U.S Ground shipping
$724.46
$603.72
Normally In Stock
Omega HX94BCNPT RH/TEMP TRANSMITTER CURRENT NPT
Free U.S Ground shipping
$673.61
$561.34
Normally In Stock
Omega HX94BCW RH/TEMP TRANSMITTER CURRENT STRIPPED LEA
Free U.S Ground shipping
$653.05
$544.21
Normally In Stock
Omega HX15-D HI-TEMP/RH TX DUCT MOUNTED
Free U.S Ground shipping
$1354.55
$1128.79
Normally In Stock
Omega HX15-W HI-TEMP/RH TX, WALL MOUNTED
Free U.S Ground shipping
$1281.68
$1068.07
Normally In Stock
Omega HX402D TRANSMITTER
Free U.S Ground shipping
$1594.39
$1328.66
Normally In Stock
Omega HX402R TRANSMITTER
Free U.S Ground shipping
$1538.66
$1282.22
Normally In Stock
Omega HX402W TRANSMITTER
Free U.S Ground shipping
$1438.33
$1198.61
Normally In Stock
Omega HX93BC TEMP/RH XMITTER WALL MNT4-20MA
Free U.S Ground shipping
$653.74
$544.78
Normally In Stock
Omega SPRTX-S2 RTD TRANSMITTER
Free U.S Ground shipping
$438.60
$365.50
Normally In Stock
Omega STCTX-K3 T/C TRANSMITTER
Free U.S Ground shipping
$212.16
$176.80
Normally In Stock
Omega SPRTX-SS1-M12-1 RTD CONNECTOR-TRANSMITTER/M12
Free U.S Ground shipping
$312.24
$260.20
Normally In Stock
Omega SPRTX-SS1-M12-1-15M RTD CONNECTOR-TRANSMITTER/M12
Free U.S Ground shipping
$516.70
$430.58
Normally In Stock
Omega SPRTX-SS1-M12-2 RTD CONNECTOR-TRANSMITTER/M12
Free U.S Ground shipping
$341.58
$284.65
Normally In Stock
Omega SPRTX-SS2-M12-1 RTD CONNECTOR-TRANSMITTER/M12
Free U.S Ground shipping
$317.53
$264.61
Normally In Stock
Omega M12TX-PT100 INLINE TRANSMITTER FOR RTD
Free U.S Ground shipping
$216.97
$180.81
Normally In Stock
Omega HX200HD Humidity Probe for Dew Point
Free U.S Ground shipping
$1595.84
$1329.87
Normally In Stock
Omega HX200HD-RS REMOTE MOUNT TEMP/DP XTR SELECT OUTPUT
Free U.S Ground shipping
$1877.10
$1564.25
Normally In Stock
Omega HX200HD-W WALL MOUNT TEMP/DP XTR CURRENT OUTPUT
Free U.S Ground shipping
$1607.56
$1339.63
Normally In Stock
Omega HX200HD-W-RS WALL MOUNT TEMP/DP XTR SELECT OUTPUT
Free U.S Ground shipping
$1877.10
$1564.25
Normally In Stock
Omega TX401 HEAD MOUNT RTD INPUT TRANSMITTER RFID
Free U.S Ground shipping
$94.75
$78.96
Normally In Stock
Omega PRTX-1 PR-12-2-100-1/4-12-E, W/TX92-1
Free U.S Ground shipping
$1122.28
$935.23
Normally In Stock
Omega PRTX94-3 PR-12-2-100-1/4-12-E,W/TX94-3
Free U.S Ground shipping
$532.28
$443.57
Normally In Stock
Omega NB1TX-J3 NB1-ICSS-14U-12, WITH TX91-J3
Free U.S Ground shipping
$975.76
$813.13
Normally In Stock
Omega HX401R Relative Humidity Transmitter with LED Display
Free U.S Ground shipping
$1293.35
$1077.79
Normally In Stock
Omega HX401D Relative Humidity Transmitter with LED Display
Free U.S Ground shipping
$1360.28
$1133.57

FAQs

Q: What do temperature transmitters and transducers do?
They take input signals from thermocouples or RTDs and convert them into standardized electrical outputs, commonly 4–20 mA or voltage, so PLCs, controllers, and data acquisition systems can measure temperature reliably.

Q: What is the difference between a temperature transmitter and a temperature transducer?
A transmitter most often outputs a current signal such as 4–20 mA for reliable transmission over longer distances. A transducer is commonly associated with voltage outputs or applications where a device provides a discrete response at a defined temperature.

Q: Why is 4–20 mA used for temperature transmission in industrial systems?
4–20 mA signals are generally more robust over long cable runs and are less susceptible to electrical noise and voltage drop compared to many voltage-based signals.

Q: What temperature sensors can be used with transmitters and transducers?
Most models are designed for common thermocouple types and RTDs (including platinum RTDs), with configuration options to match sensor type, range, and output scaling.

Q: What affects the accuracy of a temperature transmitter or transducer?
Accuracy depends on sensor type, calibration, wiring practices, environmental noise, and device specifications. The overall system accuracy also includes the connected sensor, installation method, and the receiving controller’s input resolution.

Q: When should I choose a transmitter instead of a transducer?
Transmitters are typically preferred when the signal must travel longer distances, when the environment is electrically noisy, or when the control system is designed for current-loop inputs such as 4–20 mA.

Why Buy Temperature Transmitters & Transducers from RSP Supply

RSP Supply offers temperature transmitters and transducers designed to condition thermocouple and RTD signals for industrial automation and instrumentation systems. Our selection supports common output standards and application needs, including signal conversion for PLC integration, long cable runs, and electrically noisy environments. Customers rely on RSP Supply for knowledgeable support and access to components that help maintain accurate temperature monitoring and reliable process control.